12 Royalty-Free Audio Tracks for "Psa"

00:00
02:07
I get this call from my daughter's elementary school, first week of school and already a cyber attack, messing up the entire school's computer systems. It is indeed a sad world where not even grade school kids are safe from these cyber pirates. So i tweaked the recording a bit, added panned out echo and noise reductio. Enjoy!.
Author: Mahanmahan
00:00
02:02
This is a psa for radio station kjc 81. 1 fm in oakland, ca. It is for the purpose of broadcasting concern for prescription drug abuse to the east oakland community, and includes some simple steps and resources for same.
Author: Goathouse
00:00
01:23
If you go to the largest electronics market in the world, called huaqiangbei (华强北), in shenzhen, china, you’ll notice these public security announcements about every 5 minutes or so.
Author: Bodawei
00:00
08:30
Bus ride from financial district to lone mountain.
Author: Vanoosbree
00:00
00:11
At the pudong international airport in shanghai, china, we hear a woman's voice coming from a loudspeaker located on an escalator near the departing flights. She says the following, in chinese and then in english: "please watch your luggages, hold the handrail, watch your step. ". Recorded with a sony icd-ux560f. Triadtravelogues. Com.
Author: Triadtravelogues
00:00
00:35
I quick sound of labored breathing i recorded with a blue yeti for an anti-smoking psa for school.
Author: Sam
00:00
00:19
I quick sound of a coughing fit i recorded with a blue yeti for an anti-smoking psa for school.
Author: Sam
00:00
00:57
Audio of me washing my hands in the bathroom. Perfect for a psa on using both soap and water after using the toilet.
Author: Kjsisco
00:00
00:46
If you go to the largest electronics district in the world, called huaqiangbei, in shenzhen, china, you’ll probably notice this public security announcement. This is the english version. If you are interested in the chinese version, i’ll be uploading it as a separate file. Sorry for any background noise, but this is a field recording in a busy area.
Author: Bodawei
00:00
00:37
A few cycles of my dad's home oxygen machine with a ticking battery operated clock in the background recorded in the early morning in the living room with lifecam hd3000 webcam at the end of about 16 feet of usb cable dragged out of my bedroom. He's about 6 feet away, i was with my back to the room with my camera pointed at my chest so he wouldn't think i was filming. It would seem this is the first and only oxygen machine on freesound. A full cycle seems to last from between 7 to 10 seconds. From wikipediaoxygen concentrators typically use pressure swing adsorption technology and are used very widely for oxygen provision in healthcare applications, especially where liquid or pressurised oxygen is too dangerous or inconvenient, such as in homes or in portable clinics. Oxygen concentrators are also used to provide an economical source of oxygen in industrial processes, where they are also known as oxygen gas generators or oxygen generation plants. Oxygen concentrators utilize a molecular sieve to adsorb gasses and operate on the principle of rapid pressure swing adsorption of atmospheric nitrogen onto zeolite minerals and then venting the nitrogen. This type of adsorption system is therefore functionally a nitrogen scrubber leaving the other atmospheric gasses to pass through. This leaves oxygen as the primary gas remaining. Psa technology is a reliable and economical technique for small to mid-scale oxygen generation, with cryogenic separation more suitable at higher volumes and external delivery generally more suitable for small volumes. [1]at high pressure, the porous zeolite adsorbs large quantities of nitrogen, due to its large surface area and chemical character. After the oxygen and other free components are collected the pressure drops which allows nitrogen to desorb. An oxygen concentrator has an air compressor, two cylinders filled with zeolite pellets, a pressure equalizing reservoir, and some valves and tubes. In the first half-cycle the first cylinder receives air from the compressor, which lasts about 3 seconds. During that time the pressure in the first cylinder rises from atmospheric to about 1. 5 times normal atmospheric pressure (typically 20 psi/138 kpa gauge, or 1. 36 atmospheres absolute) and the zeolite becomes saturated with nitrogen. As the first cylinder reaches near pure oxygen (there are small amounts of argon, co2, water vapour, radon and other minor atmospheric components) in the first half-cycle, a valve opens and the oxygen enriched gas flows to the pressure equalizing reservoir, which connects to the patient's oxygen hose. At the end of the first half of the cycle, there is another valve position change so that the air from the compressor is directed to the 2nd cylinder. Pressure in the first cylinder drops as the enriched oxygen moves into the reservoir, allowing the nitrogen to be desorbed back into gas. Part way through the second half of the cycle there is another valve position change to vent the gas in the first cylinder back into the ambient atmosphere, keeping the concentration of oxygen in the pressure equalizing reservoir from falling below about 90%. The pressure in the hose delivering oxygen from the equalizing reservoir is kept steady by a pressure reducing valve. Older units cycled with a period of about 20 seconds, and supplied up to 5 litres per minute of 90+% oxygen. Since about 1999, units capable of supplying up to 10 lpm have been available.
Author: Kbclx
00:00
07:20
Recorded in my dad's bedroom with lifecam hd3000 webcam. This is a much better recording than my previous oxygen concentrator file, as i hauled my desktop into the bedroom at the other end of the apartment where the machine now is, when i was home alone. The webcam is on the bed about 3 or 4 feet from the machineat the beginning of the file you hear me flip the big switch and the machine comes on with a long on beep and thumps. I edited it to start then. At 00:1. 8 what i suspect is the water pump comes on, though i may be wrong. That's when the gurgling starts though. The machine has a small reservoir for distilled water to moisten the airflow. A cup or two lasts several daysyou'll hear various hisses and thumps in a 15. 6 second cycle as it runs. At 03:03 i flip the big switch to shut the machine off, and it bubbles and gurgles away for the rest of the file, as water i assume slowly perculates back into the reservoir, the bubbling getting quieter and quieter until it doesn't even sound like bubbling anymore, until it finally ticks to a stop. At 03:16 you hear me step as i get my foot loose from the mic cord lol. At 04:13 the furnace shuts down as a car finishes going by outside in the bass register, faint traffic noises and the furnace being the only background noises you'll hear aside from my moving around a couple times, and a faint bluejay at the end. At about 07:00 you can barely hear the machine anymore, but i could hear a faint ticking with my own ears. At 07:04 the furnace comes back on. At 07:08 you'll hear a bluejay faintly calling outside and a car going by outside after, which finishes the file at 07:20. I edited out my walking to the computer to shut the recording down. From wikipediaoxygen concentrators typically use pressure swing adsorption technology and are used very widely for oxygen provision in healthcare applications, especially where liquid or pressurised oxygen is too dangerous or inconvenient, such as in homes or in portable clinics. Oxygen concentrators are also used to provide an economical source of oxygen in industrial processes, where they are also known as oxygen gas generators or oxygen generation plants. Oxygen concentrators utilize a molecular sieve to adsorb gasses and operate on the principle of rapid pressure swing adsorption of atmospheric nitrogen onto zeolite minerals and then venting the nitrogen. This type of adsorption system is therefore functionally a nitrogen scrubber leaving the other atmospheric gasses to pass through. This leaves oxygen as the primary gas remaining. Psa technology is a reliable and economical technique for small to mid-scale oxygen generation, with cryogenic separation more suitable at higher volumes and external delivery generally more suitable for small volumes. [1]at high pressure, the porous zeolite adsorbs large quantities of nitrogen, due to its large surface area and chemical character. After the oxygen and other free components are collected the pressure drops which allows nitrogen to desorb. An oxygen concentrator has an air compressor, two cylinders filled with zeolite pellets, a pressure equalizing reservoir, and some valves and tubes. In the first half-cycle the first cylinder receives air from the compressor, which lasts about 3 seconds. During that time the pressure in the first cylinder rises from atmospheric to about 1. 5 times normal atmospheric pressure (typically 20 psi/138 kpa gauge, or 1. 36 atmospheres absolute) and the zeolite becomes saturated with nitrogen. As the first cylinder reaches near pure oxygen (there are small amounts of argon, co2, water vapour, radon and other minor atmospheric components) in the first half-cycle, a valve opens and the oxygen enriched gas flows to the pressure equalizing reservoir, which connects to the patient's oxygen hose. At the end of the first half of the cycle, there is another valve position change so that the air from the compressor is directed to the 2nd cylinder. Pressure in the first cylinder drops as the enriched oxygen moves into the reservoir, allowing the nitrogen to be desorbed back into gas. Part way through the second half of the cycle there is another valve position change to vent the gas in the first cylinder back into the ambient atmosphere, keeping the concentration of oxygen in the pressure equalizing reservoir from falling below about 90%. The pressure in the hose delivering oxygen from the equalizing reservoir is kept steady by a pressure reducing valve. Older units cycled with a period of about 20 seconds, and supplied up to 5 litres per minute of 90+% oxygen. Since about 1999, units capable of supplying up to 10 lpm have been available.
Author: Kbclx
1 - 12 of 12
/ 1